| Item Name | Analyzer Clinical Chemistry |
| INC Code | 42054 |
| Federal Supply Group (FSG) | Instruments And Laboratory Equipment |
| Federal Supply Class (FSC) | 6630 Chemical Analysis Instruments |
| National Item Identification Number (NIIN) | 01-490-3594 (014903594) |
| NCB Code | USA (01) |
| Manufacturer | Alfa Wassermann Inc |
| Associated Parts Numbers of NSN 6630-01-490-3594 | ||||||
|---|---|---|---|---|---|---|
| Part Number | Manufacturer | Item Name | Cage Code | Type | Status | RFQ |
| 01-0486 | alfa wassermann inc | analyzer clinical chemistry | 1qy50 | A | A | RFQ |
| 6630NCM010360 | alfa wassermann inc | analyzer clinical chemistry | 1qy50 | A | A | RFQ |
| 402444 | alfa wassermann inc | analyzer clinical chemistry | 1qy50 | A | A | RFQ |
| MRC | Criteria | Characteristic |
|---|---|---|
| ELEC | VOLTAGE IN VOLTS | 100.0 AND 120.0 |
| DPTH | DEPTH | 25.800 INCHES |
| ABRN | HEIGHT | 24.000 INCHES |
| CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | ANALYZER CLINICAL CHEM KINETIC ENZYME/RATE TEST 100/120V50/60HZ |
| WDTH | WIDTH | 27.500 INCHES |
| FEAT | SPECIAL FEATURES | COMPACT SIZE TABLE TOP DESIGN; REQUIRES 36 INCHES ABOVE ANALYZER; TAKES UP ONLY 4 SQUARE FEET OF SPACE; CLOSED TUBE SAMPLING MINIMIZES RISK FROM BLOOD BORNE PATHOGENS; WITH NEXCT ON-BOARD COMPUTER THAT IDENTIFES AND TRACK SAMPLES AND REAGENT BY LOT NUMBER, EXPIRATION DATE AND AMOUNT OF REAGENT REMAINING FOR AN ULTRA-SECURE, WORRY FREE SYSTEM; UP TO 150 SAMPLES AND 20 SEPARTE TEST REAGENTS MAY BE PLACED ON-BOARD AND EFFECTS SUCH AS EXPOSURE TO LIGHT AND EVAPORATION ARE KEPT TO AN ABSOLUTE MINIMUM; SINGLE PROBE HANDLES ALL SAMPLE AND REAGENT ASPIRATION AND DISPENSE FUNCTIONS; NEW CUVETTE FOR EACH REACTION ELIMINATES CHANCE OF CROSS CONTAMINATION; UP TO 58 CUVETTES CAN BE STORED ON-BOARD AT ANYTIME; IMMEDIATE STAT INTERRUPT; AUTO REPEAT AND DILUTION; MULTI-TASKING INTELLIGENT SOFTWARE OFFERS INDIVIDUAL PROFILE, BATCH OR STAT ASSAYS; INTEGRATED COMPUTER, MONOCHROME MONITOR; EXTERNAL PRINTER AND RELATED SUPPLIES; COLOR CODED PROMPTS; BUILT IN SELF DIAGNOSTICS |
| ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
| CYFV | METHOD OF ANALYSIS | KINETIC ENZYME/RATE TEST |
| ACDC | CURRENT TYPE | AC |
| Relevant Components for NSN - 6630-01-490-3594, 6630014903594 | ||||
| 6630-01-508-9602 (6630015089602) | 6630-01-042-2632 (6630010422632) | 6630-01-623-9036 (6630016239036) | 6630-01-328-8073 (6630013288073) | |
| 6630-01-149-4487 (6630011494487) | 6630-01-508-9912 (6630015089912) | 6630-01-546-4554 (6630015464554) | 6630-00-255-9135 (6630002559135) | |
| 6630-01-440-2975 (6630014402975) | 6630-01-050-9330 (6630010509330) | 6630-01-267-1582 (6630012671582) | 6630-00-330-4350 (6630003304350) | |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!
Request for Quote