We've received your request for PU200-45C (described as Power Supply), manufactured by Coda Octopus Ltd with CAGE code 64014. This part is registered under NSN 6130-01-517-8201, classified in FSG / FSC . Our verification process will confirm traceability through supporting identifiers including NIIN 01-517-8201, NCB code 01 (origin: USA), and INC 00740. Please submit your formal quotation request to proceed.
Thank you for choosing Aerospace Exchange for your PU200-45C requirements. We specialize in authenticated aerospace components, offering both NSN-tracked military parts and commercial equivalents, all validated through our rigorous sourcing protocols.
How to Begin the Quotation Process
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 6130-01-517-8201 Item PartTypeName: POWER SUPPLY | 6130 | 015178201 | 0 | N | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | 0 | ||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| PU200-45C | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABMK | OVERALL WIDTH | 5.000 INCHES NOMINAL |
| AGAV | END ITEM IDENTIFICATION | AN/USM TEST SET, SONAR DETECTING |
| ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
| BGQR | OUTPUT WATTAGE RATING | 200.0 WATTS NOMINAL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| CWGN | OUTPUT PHASE | SINGLE MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| CWGZ | RIPPLE VOLTAGE AT FULL LOAD | 2.0 VOLTS PEAK MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| CWHT | INPUT CONNECTION QUANTITY | 1 SINGLE OPERATING POWER RQMT |
| CWKG | VENTILATION DESIGN TYPE | AIR COOLED |
| CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP SINGLE OPERATING POWER RQMT |
| APPA | OUTPUT VOLTAGE RATING | -12.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
| APNX | INPUT VOLTAGE RATING | 90.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 264.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | SWITCHING POWER SUPPLY |
| CWGW | POWER SUPPLY OUTPUT CURRENT/VOLTAGE CHARACTERISTICS | CONSTANT CURRENT MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| CWHF | OUTPUT CONNECTION QUANTITY | 4 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
| CWHM | INPUT CURRENT RATING | 4.5 AC AMPERES MINIMUM AND 2.6 AC AMPERES MAXIMUM SINGLE OPERATING POWER RQMT |
| CWGH | OUTPUT CURRENT RATING | 3.0 DC AMPERES MINIMUM AND 30.0 DC AMPERES MAXIMUM 1ST POWER OUTPUT 8.0 DC AMPERES MINIMUM AND 12.0 DC AMPERES MAXIMUM 2ND POWER OUTPUT 0.0 DC AMPERES MINIMUM AND 4.0 DC AMPERES MAXIMUM 3RD POWER OUTPUT 0.0 DC AMPERES MINIMUM AND 4.0 DC AMPERES MAXIMUM 4TH POWER OUTPUT |
| BHQN | RECTIFICATION METHOD | MAGNETIC AMPLIFIER OPEN BRIDGE |
| AYNH | OPERATING AMBIENT TEMP RANGE | 0.1 TO 70.0 DEG CELSIUS |
| AMQY | INSTALLATION DESIGN | HOLE |
| ABHP | OVERALL LENGTH | 9.000 INCHES NOMINAL |
| APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
| ABKW | OVERALL HEIGHT | 2.550 INCHES NOMINAL |
| End Use : 20000 | Generators, accessories |
|---|---|
| Schedule B : 8504900080 (NAICS 334419) | Static converter & inductor parts, nesoi |
| SITC : 77129 | Parts of electric power machinery (other than rotating electric power generating machinery and equipment), and parts thereof |
| ADPE | Represents items with no adp components |
|---|---|
| CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| HMIC | N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials. |
| PMIC | A - Item does not contain precious metal. |
| AAC | Z |
|---|---|
| Classification Control | U |
| MGMT_CTL | 9b----- |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | Sms |
| Unit of Measure | Ea |
| ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
|---|---|
| ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
| LTL: | M - 85.0 |
| NMFC: | 062900 - Rectifiers noi/battery eliminators |
| SHC: | 9 - Other or no special handling required (sh) |
| TCC: | Z - No special type of cargo code applicable |
| WCC: | 595 - Transformer, (machinery and parts),(less than 35 feet) |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!