We've received your request for AM3R-A39-LC07D-A52 (described as Circuit Breaker), manufactured by Wesco Distribution Inc with CAGE code 0UZ78. This part is registered under NSN 5925-01-248-5793, classified in FSG 59 Electrical and Electronic Equipment Components / FSC 5925 Circuit Breakers. Our verification process will confirm traceability through supporting identifiers including NIIN 01-248-5793, NCB code 01 (origin: USA), and INC 00136. Please submit your formal quotation request to proceed.
Thank you for choosing Aerospace Exchange for your AM3R-A39-LC07D-A52 requirements. We specialize in authenticated aerospace components, offering both NSN-tracked military parts and commercial equivalents, all validated through our rigorous sourcing protocols.
How to Begin the Quotation Process
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-248-5793 Item PartTypeName: CIRCUIT BREAKER | 5925 | 012485793 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | U | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| AM3-A39-A-40-252 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| ADAQ | BODY LENGTH | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 2.240 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AGAV | END ITEM IDENTIFICATION | AIR ROUTE SURVEILLANCE RADAR 1,FA7171 AMPLITRON POWER SUPPLY CABINET; ARSR-2,FA7121 AMPLITRON POWER SUPPLY CABINET |
| AJEC | BOSS HEIGHT | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM |
| AKPX | POLE QUANTITY | 3 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED STUD |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 40.0 AMPERES AC ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 130.0 ALL LOCATIONS |
| CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 10.000 NOMINAL ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE,TWO,AND THREE LINKED |
| CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 77.0 DEG FAHRENHEIT NOMINAL ALL LOCATIONS |
| CWJK | CASE MATERIAL | PLASTIC |
| FEAT | SPECIAL FEATURES | FUNCTION: CIRCUIT BREAKER,MAGNETIC,40 AMP; REFERENCE DATA: CB-4401,INSTRUCTION BOOK ARSR-1D/E/F,VOL 5,SEC 10,PG 10-759; CB-4401,INSTRUCTION BOOK ARSR-2,VOL 5,SEC 10,PG 10-563 |
| FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| THSD | THREAD SERIES DESIGNATOR | UNC |
| TTQY | TERMINAL TYPE AND QUANTITY | 9 TAB,SOLDER LUG OR 6 THREADED STUD |
| End Use : 20005 | Electric apparatus |
|---|---|
| Schedule B : 8536200040 (NAICS 335313) | Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi |
| SITC : 77252 | Automatic circuit breakers for a voltage not exceeding 1, 000 volts |
| CRITL | The item does not have a critical feature such as tolerance, fit restrictions or application. nuclear hardness properties have not been determined (not valid for input). |
|---|---|
| HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
| PMIC | U - Precious metal content is unknown |
| AAC | G |
|---|---|
| Classification Control | U |
| MGMT_CTL | ------- |
| Quantity per pack | 1 |
| Repariability | |
| Shelf Life | N/A |
| SOS | G69 |
| Unit of Measure | Ea |
![]() |
AS9120B and ISO 9001:2015 |
![]() |
Aviation Suppliers Association Member |
![]() |
FAA AC 0056B Accredited |
![]() |
AS 6081:2012 Certification |
![]() |
ESD S20.20-2014 Certification |
Don’t forget That We offer 24/7 Service, Competitive Prices, and Fast Deliveries. We Hope You'll Make Us Your One-Stop Purchasing Solution!